General
 | 
| Part Number | 
A9K-24X10GE-SE | 
| Product Description | 
Cisco ASR 9000 24-Port 10GE Service Edge Optimized Line Card, requires SFP+ optics | 
| Chassis compatibility | 
Compatible with the Cisco ASR 9000 Series 22-slot, 10-slot, and 6-slot chassis | 
| Port density | 
24 ports of 10 Gigabit Ethernet per line card | 
| Ethernet | 
●  10-Gbps IEEE 802.3 compliant
 ●  10 Gigabit Ethernet PHY monitoring 
●  IEEE 802.x flow control 
●  Full-duplex operation 
●  Per-port byte and packet counters for policy drops; oversubscription drops; cyclic redundancy check (CRC) error drops; packet sizes; and unicast, multicast, and broadcast packets  | 
| Performance | 
●  10-Gbps line-rate throughput per port | 
| Options | 
Each line card is available as either a Service Edge Optimized (enhanced QoS) or Packet Transport Optimized (basic QoS) line card | 
| Reliability and availability | 
Line card online insertion and removal (OIR) support without system impact | 
| Physical dimensions (H x W x D); weight | 
14 x 1.72 x 20.5 in.; 14 lb (35.56 x 4.37 x 52.07 cm; 6.35 kg) | 
| Network Equipment Building Standards (NEBS) | 
Cisco ASR 9000 Series Routers are designed to meet:
 ●  SR-3580: NEBS Criteria Levels (Level 3) 
●  GR-1089-CORE: NEBS EMC and Safety 
●  GR-63-CORE: NEBS Physical Protection  | 
| Operating temperature (nominal) | 
41 to 104ºF (5 to 40ºC) | 
| Operating temperature (short-term) | 
23 to 131ºF (–5 to 55ºC)
 Note: Short-term refers to a period of not more than 96 consecutive hours and a total of not more than 15 days in 1 year (total of 360 hours in any given year, but no more than 15 occurrences during that 1-year period).  | 
| Operating humidity (nominal) (relative humidity) | 
10 to 85% | 
| Storage temperature | 
-40 to 158ºF (-40 to 70ºC) | 
| Storage (relative humidity) | 
5 to 95%
 Note: Not to exceed 0.024 kg of water per kg of dry air  | 
| Operating altitude | 
-60 to 4000m (up to 2000m conforms to IEC, EN, UL, and CSA 60950 requirements) | 
| ETSI standards | 
Cisco ASR 9000 Series Routers are designed to meet:
 ●  EN300 386: Telecommunications Network Equipment (EMC) 
●  ETSI 300 019 Storage Class 1.1 
●  ETSI 300 019 Transportation Class 2.3 
●  ETSI 300 019 Stationary Use Class 3.1 
●  EN55022: Information Technology Equipment (Emissions) 
●  EN55024: Information Technology Equipment (Immunity) 
●  EN50082-1/EN-61000-6-1: Generic Immunity Standard  | 
| EMC standards | 
Cisco ASR 9000 Series Routers are designed to meet:
 ●  FCC Class A 
●  ICES 003 Class A 
●  AS/NZS 3548 Class A 
●  CISPR 22 (EN55022) Class A 
●  VCCI Class A 
●  BSMI Class A 
●  IEC/EN 61000-3-2: Power Line Harmonics 
●  IEC/EN 61000-3-3: Voltage Fluctuations and Flicker  | 
| Immunity | 
Cisco ASR 9000 Series Routers are designed to meet:
 ●  IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air) 
●  IEC/EN-61000-4-3: Radiated Immunity (10V/m) 
●  IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal) 
●  IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM) 
●  IEC/EN-61000-4-5: Signal Ports (1kV) 
●  IEC/EN-61000-4-5: Surge DC Port (1kV) 
●  IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms) 
●  IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m) 
●  IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations  | 
| Safety | 
Cisco ASR 9000 Series Routers are designed to meet:
 ●  UL/CSA/IEC/EN 60950-1 
●  IEC/EN 60825 Laser Safety 
●  ACA TS001 
●  AS/NZS 60950 
●  FDA – Code of Federal Regulations Laser Safety  | 
 
There are no reviews yet.