, , , , ,

Planet ICS-2102T – Industrial 1-port RS232/422/485 Serial Device Server with 1-Port 100BASE-FX SFP

Planet
Availability:

Available on backorder


Model No – ICS-2102T

  • IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100FX SC, MM/2km)
  • One DB9 interface that supports RS232
  • One terminal block interface that supports 2-wire RS485 and 4-wire RS422/RS485 standards
  • Asynchronous serial data rates up to 921600bps
  • Data modes include VCOM, RFC2217, TCP Server, TCP Client, UDP, Remote Pair, Modbus converter server/client, and Serial Telnet modes
  • 1-port 100BASE-FX SFP slot
  • IPv4 and IPv6 dual stack management
  • Remote Management Interfaces
  • IP30 metal case
  • Supports 6000 VDC Ethernet ESD protection
  • -40 to 75 degrees C operating temperature
  • Free fall, shock-proof and vibration-proof for industries
  • DIN-rail and wall-mount designs
  • Redundant power design

     Product Availability : On Order Basis, 4-8 Weeks

Cost-effective Solution for RS232/422/485 Serial-to-Industrial Ethernet Application

PLANET ICS-2105AT Serial Device Server is specially designed to convert RS232, RS422 or RS485 serial communication to Industrial Fast Ethernet networking so as to extend the network distance efficiently and inexpensively. There is one 100BASE-FX single-mode/multi-mode media available in the ICS-2105AT and its operating temperature ranges from -40 to 75 degrees C for your network needs. The ICS-2105AT is a time-saving and cost-effective solution for users and system integrators to quickly transform their serial devices into the Ethernet network with no need of replacing the existing serial devices and software system.

Efficiently Extend Network Distance

The ICS-2105AT especially equips one SFP fiber slot (mini-GBIC 100Base-FX SFP or small-form factor pluggable) and is able to extend the distance of deploying serial equipment and hosts. Users are able to select fiber-optic cables (based on distance) provided for distance extension from 550 meters (via multi-mode fiber) to 120 kilometers (via single-mode fiber) or longer.

Remote Management 

As the ICS-2105AT provides easy serial-to-Ethernet connectivity and connection to a TCP/IP network, the remote network system can thus be managed efficiently via its Web, telnet, and VCOM management interfaces. It supports both application and serial operation modes for alarm or IP address connection, which saves the network administrator’s time in detecting and locating network problems without visual inspection of the cabling and devices. Multiple connection options are available for a large networking environment as well.

Stable Performance under Difficult Environments

The ICS-2105AT provides a high level of immunity against electromagnetic interference and heavy electrical surges which are usually found on plant floors or in curbside traffic control cabinets. Its operating temperature ranging from -40 to 75 degrees C allows the ICS-2105AT to be placed in almost any difficult environment.

The ICS-2105AT with compact IP30 standard metal case allows either DIN-rail or wall mounting for efficient use of cabinet space. The ICS-2105AT also provides an integrated power supply source with a wide range of voltages (9 to 48V DC / 24V AC) ideally suitable for worldwide operation with high availability applications requiring dual or backup power inputs.

Dual Power Input for High Availability Network System

The ICS-2105AT features a strong dual power input system with wide-ranging voltages (9V~48V DC / 24V AC) incorporated into customer’s automation network to enhance system reliability and uptime. In the example below, when Power Supply 1 fails to work, the hardware failover function will be activated automatically to keep powering the ICS-2105AT via Power Supply 2 without any break of operation.

Effective Alarm Alert for Better Protection

The ICS-2105AT comes with a Fault Alarm feature which can alert the users when there is something wrong with the Serial Device Server. With this ideal feature, the users would not have to waste time finding where the problem is. It will help to save time and human resource. The ICS-2105AT provides event alert function to help to diagnose the abnormal device owing to whether or not there is a break of the network connection, or the rebooting response.

Serial Interface
Serial Ports ICS-2105AT
1 x DB9 male for RS232
1 x 4-Pin Terminal block for RS422 / RS485ICS-2102T
1 x DB9 male for RS232
1 x 4-Pin Terminal block for RS422 / RS485ICS-2102TS
1 x DB9 male for RS232
1 x 4-Pin Terminal block for RS422 / RS485
Serial Standards RS232 / 4-wire RS422 or RS485 / 2-wire RS485
Baud Rate (Data Rate) 50bps to 921Kbps
Data Bits 5, 6, 7, 8
Parity Type 1, 1.5, 2
Stop Bit Odd, Even, None, Space, Mark
Flow Control RTS/CTS and DTR/DSR (RS232 only)
XON/XOFF
Signals RS232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS422: Tx+, Tx-, Rx+, Rx-, GND
4-wire RS485: Tx+, Tx-, Rx+, Rx-, GND
2-wire RS485: Data A (+), Data B (-), GND
Pin Assignment Serial Port

Pin RS232 RS422
RS485-4W
RS485-2W
1 DCD TxD+
2 RxD TxD-
3 TxD RxD- Data-
4 DTR RxD+ Data+
5 GND GND GND
6 DSR
7 RTS
8 CTS
9

4-pin Terminal Block

Pin RS422
RS485-4W
RS485-2W
1 TxD+(A)
2 TxD-(B)
3 RxD-(B) Data-(B)
4 RxD+(A) Data+(A)
Ethernet Interface
Ethernet Ports ICS-2105AT: 1 x SFP
ICS-2102T/ICS-2102TS: 1 x Duplex SC
Standard 100BASE-FX
Connector ICS-2105AT: LC
ICS-2102T/ICS-2102TS: Duplex SC
Fiber Mode ICS-2105AT: Single mode or multi-mode (may vary on SFP module)
ICS-2102T: Multi-mode
ICS-2102TS: Single mod
Transmission Mode Full duplex
Distance ICS-2105AT: 2km to 120km (may vary on SFP module)
ICS-2102T: 2km
ICS-2102TS: 30km
Cable ICS-2105AT:
50 or 62.5/125μm multi-mode fiber cable
9/125μm single-mode cableICS-2102T: 50/125μm or 62.5/125μm multi-mode fiber cableICS-2102TS: 9/125μm single-mode cable
ESD Protection 6KV
Surge Protection 2KV
Hardware
Installation DIN-rail kit and wall-mount ear
Enclosure IP 30 metal
Dimensions (W x D x H) 32 x 87.8 x 135 mm
Weight ICS-2105AT: 390g
ICS-2102T: 386g
ICS-2102TS: 391g
LED Indicators System: Power 1, Power 2, Fault, SYS
SFP: Link/Active
Serial Port: Tx and Rx
Power Requirements 9~48V DC / 24V AC, redundant power with reverse polarity protection
Power Consumption ICS-2105AT:
Full Loading
9VDC: 0.44A (3.96 watts)
12VDC: 0.33A (4 watts)
24VDC: 0.17A (4.08 watts)
48VDC: 0.1A (4.8 watts)ICS-2102T:
Full Loading
9VDC: 0.56A (5 watts)
12VDC: 0.42A (5 watts)
24VDC: 0.23A (5.5 watts)
48VDC: 0.13A (6 watts)ICS-2102TS:
Full Loading
9VDC: 0.56A (5 watts)
12VDC: 0.42A (5 watts)
24VDC: 0.23A (5.5 watts)
48VDC: 0.13A (6 watts)
Connector Removable 6-pin terminal block for power input
Pin 1/2 for Power 1, Pin 3/4 for fault alarm, Pin 5/6 for Power 2
Alarm Provides one relay output for power failure
Alarm relay current carry ability: 1A @ DC 24V
Reset Button < 5 sec: System reboot > 5 sec: Factory default
Management
Management Interfaces Web management
Telnet Console management
Windows-based VCOM Utility management
SNMPv1, v2c / SNMP Trap
UNI-NMS monitoring
PLANET Smart Discovery Utility
IP Version IPv4 and IPv6
Operation Mode TCP Server
TCP Client
UDP Client
Virtual COM
RFC2217
Telnet Server
Pair Connection – Remote (Slave)
Pair Connection – Local (Master)
Modbus converter server / client
Virtual COM Utility Platform Supports Windows-based only:
Windows XP
Windows Server 2003
Windows 7
Windows Server 2008
Windows 8 (Must install the latest version of WinPcap)
Windows Server 2012 (Must install the latest version of WinPcap)
Windows 10
Security Allows maximum 4 accessible IP address hosts/ranges
SNMP MIBs RFC1213 MIB-II
RFC1317 RS232-like MIB
Standards Conformances
Regulatory Compliance FCC Part 15 Class A,
CE Certification Class A
RoHS
Stability Testing IEC60068-2-32 (Free fall)
IEC60068-2-27 (Shock)
IEC60068-2-6 (Vibration)
Standards IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-FX
RFC 768 UDP
RFC 793 TFTP
RFC 791 IP
RFC 792 ICMP
RFC 854 Telnet
RFC 958 NTP
RFC 1591 DNS (client only)
RFC 1908 SNMPv2c
RFC 2068 HTTP
RFC 2131 DHCP Client
RFC 2732 Format for Literal IPv6 Addresses in URL’s
RFC 3315 DHCPv6 Client
RFC 3513 IPv6 Addressing Architecture
RFC 3596 DNSv6
RFC 4443 ICMPv6
EIA/TIA RS232/422/485

Based on 0 reviews

0.0 overall
0
0
0
0
0

Only logged in customers who have purchased this product may leave a review.

There are no reviews yet.

Do you have a question?

Drop us a line by compiling the form below. We will be more than happy to reply to any of your questions!










    Please prove you are human by selecting the flag.

    ICS-2102T Datasheet

    Download

    You may also like…