General
|
Description |
Cisco ASR 9006 Chassis, ASR-9006-AC, ASR-9006 AC Chassis |
Cisco ASR 9006 Specs
|
Physical specifications |
Height: 17.50 in. (444.5 mm) (10 RU)
Width: 17.38 in. (441.45 mm)
Depth:
· With doors: 29.05 in. (737.9 mm)
· Without doors: 29.05 in. (737.9 mm)
Weight:
· 89.55 lb (40.7 kg) (chassis with PEM)
150 lb (65.91 kg) (fully loaded, excluding line cards and power modules) – RSP, two v2 FAN trays, PEMs |
Slot orientation |
Horizontal |
Cisco ASR 9000 Series RSP |
Dual redundant RSPs with integrated fabric in 2 slots |
Cisco ASR 9000 Series line cards |
4 line-card slots |
“Commons” components |
2 RSPs
2 fan trays
1 PEM (either DC or AC)
1 fan filter |
Reliability and availability |
Fabric redundancy
Fan redundancy
Feed redundancy
Power-supply redundancy
RSP redundancy
Software redundancy |
Rack mounting |
19-in. default
21- and 23-in. adapters available
Note: Minimum 17.75-in. opening between posts is needed for proper operation |
Cabinet mounting |
Yes
Note: Doors not recommended in enclosed cabinets |
Wall mounting |
No |
Airflow |
Right-to-back, Front-to-back with baffle |
Performance
|
Fabric |
One per RSP:
· Active/active nonblocking operation mode in dual-RSP redundant configuration
· Fully redundant in dual-RSP redundant configuration
· Built-in service-intelligence and traffic-prioritization capability |
Thermal |
Two fan trays:
· 6 high-efficiency fans per tray
· Variable-speed fans for optimal thermal performance
· No single point of failure |
Power
|
Modularity |
Pay-as-you-grow power for future scalability, available in AC and DC.
Multiple power module types:
· 3 kW AC power module
· 2.1 kW DC power module
Note: Mixing of AC and DC modules is not supported |
Redundancy |
· AC: N+N redundancy
· DC: N+1 redundancy
· Power module redundancy
· A/B Feed redundancy |
Power zones |
No power zone restrictions
Fully load-sharing power infrastructure |
Power input |
Worldwide ranging AC (200-240V; 50-60 Hz; 16A maximum)
Worldwide ranging DC (-40 to -72V; 50A nominal, 60A maximum) |
Power-module airflow |
Front-to-back |
Operating temperature (nominal)
|
41 to 104ºF (5 to 40ºC)
|
Operating temperature (short-term)
|
ASR 9006: 23 to 131ºF (-5 to 55ºC)
ASR 9010: 23 to 122ºF (-5 to 50ºC)
|
Operating humidity (nominal) (relative humidity)
|
5 to 90%
|
Storage temperature
|
-40 to 158ºF (-40 to 70ºC)
|
Storage (relative humidity)
|
5 to 93%
|
Operating altitude
|
-60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)
|
Network Equipment Building Standards (NEBS)
|
Cisco ASR 9006 is designed to meet:
· SR-3580: NEBS Criteria Levels (Level 3)
· GR-1089-CORE: NEBS EMC and Safety
· GR-63-CORE: NEBS Physical Protection
· VZ.TPR.9205: Verizon TEEER
|
ETSI standards
|
Cisco ASR 9006 is designed to meet:
· EN300 386: Telecommunications Network Equipment (EMC)
· ETSI 300 019 Storage Class 1.1
· ETSI 300 019 Transportation Class 2.3
· ETSI 300 019 Stationary Use Class 3.1
|
EMC standards emission
|
Cisco ASR 9006 is designed to meet:
· FCC Class 47CFR15 A
· ICES 003 Class A
· AS/NZS CISRP22 Class A
· CISPR 22 (EN55022) Class A
· VCCI Class A
· BSMI Class A
· IEC/EN 61000-3-12: Power Line Harmonics
· IEC/EN 61000-3-11: Voltage Fluctuations and Flicker
· EN55022: Information Technology Equipment (Emissions)
· EN 50121-4: Railway EMC
|
EMC standards immunity
|
Cisco ASR 9006 is designed to meet:
· IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)
· IEC/EN-61000-4-3: Radiated Immunity (10V/m)
· IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)
· IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)
· IEC/EN-61000-4-5: Signal Surge Ports (1kV)
· IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM)
· IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
· IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)
· IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations
· EN55024: Information Technology Equipment (Immunity)
· EN50082-1/EN-61000-6-1: Generic Immunity Standard
· EN 50121-4: Railway EMC
|
Safety
|
Cisco ASR 9006 is designed to meet:
· UL/CSA/IEC/EN 60950-1
· IEC/EN 60825 Laser Safety
· ACA TS001
· AS/NZS 60950
· FDA Code of Federal Regulations Laser Safety
|