CISCO ASR-9006-AC-V2

Cisco

  • ASR-9006-AC-V2 is the Cisco ASR-9006 AC Chassis with PEM Version 2. The Cisco ASR 9000 Series has a modular power architecture available in both AC and DC. The power supplies are housed in field-serviceable Power Entry Modules (PEMs), which also come in AC and DC forms. Each PEM can hold up to three or four modules depending on its corresponding type, with no power zones or placement restrictions (mixing of AC and DC supplies is not supported). To provide ASR 9006 functions, ASR-9006-AC-V2 needs to be configured with necessary components separately.

රු350,000.00

Cisco ASR 9000 Series Aggregation Services Routers

Cisco ASR 9000 Series Aggregation Services Routers

High performance routers built to serve demanding edge markets

 

Edge networks serve billions of devices with low-latency services. You need feature rich routers that economically scale with bandwidth demand.The ASR 9000 series is your edge routing device capable of supporting the application performance required to power 5G service needs.

SKU: CISCO ASR-9006-AC-V2 Category:
brands

Cisco

Sub Brands

 

General

Description Cisco ASR 9006 System ASR-9006-AC-V2 ASR 9006 AC Chassis with PEM Version 2

Cisco ASR 9006 Specs

Physical specifications Height: 17.50 in. (444.5 mm) (10 RU)

Width: 17.38 in. (441.45 mm)

Depth:

●  With doors: 29.05 in. (737.9 mm)

●  Without doors: 29.05 in. (737.9 mm)

Weight:

●  89.55 lb (40.7 kg) (chassis with PEM)

150 lb (65.91 kg) (fully loaded, excluding line cards and power modules) – RSP, two v2 FAN trays, PEMs

Slot orientation Horizontal
Cisco ASR 9000 Series RSP Dual redundant RSPs with integrated fabric in 2 slots
Cisco ASR 9000 Series line cards 4 line-card slots
“Commons” components 2 RSPs

2 fan trays

1 PEM (either DC or AC)

1 fan filter

Reliability and availability Fabric redundancy

Fan redundancy

Feed redundancy

Power-supply redundancy

RSP redundancy

Software redundancy

Rack mounting 19-in. default

21- and 23-in. adapters available

Note: Minimum 17.75-in. opening between posts is needed for proper operation

Cabinet mounting Yes

Note: Doors not recommended in enclosed cabinets

Wall mounting No
Airflow Right-to-back, Front-to-back with baffle

Performance

Fabric One per RSP:

●  Active/active nonblocking operation mode in dual-RSP redundant configuration

●  Fully redundant in dual-RSP redundant configuration

●  Built-in service-intelligence and traffic-prioritization capability

Thermal Two fan trays:

●  6 high-efficiency fans per tray

●  Variable-speed fans for optimal thermal performance

●  No single point of failure

Power

Modularity Pay-as-you-grow power for future scalability, available in AC and DC.

Multiple power module types:

●  3 kW AC power module

●  2.1 kW DC power module

Note: Mixing of AC and DC modules is not supported

Redundancy ●  AC: N+N redundancy

●  DC: N+1 redundancy

●  Power module redundancy

●  A/B Feed redundancy

Power zones No power zone restrictions

Fully load-sharing power infrastructure

Power input Worldwide ranging AC (200-240V; 50-60 Hz; 16A maximum)

Worldwide ranging DC (-40 to -72V; 50A nominal, 60A maximum)

Power-module airflow Front-to-back

Operating temperature (nominal)

41 to 104ºF (5 to 40ºC)

Operating temperature (short-term)

ASR 9006: 23 to 131ºF (-5 to 55ºC)

ASR 9010: 23 to 122ºF (-5 to 50ºC)

Operating humidity (nominal) (relative humidity)

5 to 90%

Storage temperature

-40 to 158ºF (-40 to 70ºC)

Storage (relative humidity)

5 to 93%

Operating altitude

-60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)

Network Equipment Building Standards (NEBS)

Cisco ASR 9006 is designed to meet:

●  SR-3580: NEBS Criteria Levels (Level 3)

●  GR-1089-CORE: NEBS EMC and Safety

●  GR-63-CORE: NEBS Physical Protection

●  VZ.TPR.9205: Verizon TEEER

ETSI standards

Cisco ASR 9006 is designed to meet:

●  EN300 386: Telecommunications Network Equipment (EMC)

●  ETSI 300 019 Storage Class 1.1

●  ETSI 300 019 Transportation Class 2.3

●  ETSI 300 019 Stationary Use Class 3.1

EMC standards emission

Cisco ASR 9006 is designed to meet:

●  FCC Class 47CFR15 A

●  ICES 003 Class A

●  AS/NZS CISRP22 Class A

●  CISPR 22 (EN55022) Class A

●  VCCI Class A

●  BSMI Class A

●  IEC/EN 61000-3-12: Power Line Harmonics

●  IEC/EN 61000-3-11: Voltage Fluctuations and Flicker

●  EN55022: Information Technology Equipment (Emissions)

●  EN 50121-4: Railway EMC

EMC standards immunity

Cisco ASR 9006 is designed to meet:

●  IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)

●  IEC/EN-61000-4-3: Radiated Immunity (10V/m)

●  IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)

●  IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)

●  IEC/EN-61000-4-5: Signal Surge Ports (1kV)

●  IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM)

●  IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)

●  IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)

●  IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations

●  EN55024: Information Technology Equipment (Immunity)

●  EN50082-1/EN-61000-6-1: Generic Immunity Standard

●  EN 50121-4: Railway EMC

Safety

Cisco ASR 9006 is designed to meet:

●  UL/CSA/IEC/EN 60950-1

●  IEC/EN 60825 Laser Safety

●  ACA TS001

●  AS/NZS 60950

●  FDA Code of Federal Regulations Laser Safety

 

Based on 0 reviews

0.0 overall
0
0
0
0
0

Only logged in customers who have purchased this product may leave a review.

There are no reviews yet.

Do you have a question?

Drop us a line by compiling the form below. We will be more than happy to reply to any of your questions!










    Please prove you are human by selecting the heart.

    Data Sheet

    Download